HEMATOLOGY ANALYZER

TECHNICAL SPECIFICATIONS

FEATURES
1. 20 Parameters +3 Histograms for WBC, RBC and PLT.

2. 3-Part differentiation of WBC.

3. 3 Counting mode: whole blood, pre-diluted blood, peripheral blood.

4. LCD display with Touch Screen and Mouse Operation.

5. Throughput: 60 samples per hour.

6. Built-in thermal printer, optional external printer.

7. External AC adapter avoids electronic noises, enhancing accuracy

8. Up to 50,000 sample results (including histograms) stored.

9. Language: English, French, Spanish.

             

Parameters:

WBC, RBC, HGB, MCHC, MCH, MCV, HCT, RDW-CV, RDW-SD, PLT
PDW, MPV, PCT, P-LCR, LYM#, LYM%, MID#, MID%, GRA#, GRA%

3 Histograms for WBC, RBC, PLT

Throughput: Up to 60 samples per hour

Carryover: WBC/RBC/HGB < 0.5%, PLT < 1.0%

HEMAX 330

AUTOMATED HEMATOLOGY ANALYZER

hemax 330.jpg
TECHNICAL SPECIFICATIONS

AUTOMATED HEMATOLOGY ANALYZER

PCCD 5000

Parameters

WBC, LY#, MID#, GR#, LY%, MID%, GR%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, DRW-CV, PLT, MPV, PDW, PCT, P-LCR and Histogarm for WBC, RBC, PLT

Method

Coulter Principle

Colorimtery hamoglobin determination

Performance

Parameter                 Linearity Range                 Precision(CV%)

WBC (10⁹/L)               0.0-99.9                              2.5 (7.0-15.00

RBC (1022/L)              0.00-9.99                            2.0 (3.50-6.00)

HGB (g/L)                    0-300                                  1.5 (110-180)

MCV (fL)                      40.0-150.0                          0.5 (80.0-110.0)

PLT (10⁹/L)                 0-999                                   5.0 (200-500)

Throughput

60 samples per hour

Menu

Review, Test, Maintenance, QC, Setup, Shutdown, Prime reagents, System diagnosis, Aperture rinse, Soak and Rinse, Calibration, instrument config.

Display

8.0" color LCD display

Sampler Volume

Predilute            20uL

Whole blood     15uL

pccd5000.JPG

Parameters

WBC, LY#, MID#, GR#, LY%, MID%, GR%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, PDW, PCT, P-LCR, P-LCC and Histogarm for WBC, RBC, PLT

Principles

Electrical impedance method for cell counting and cyanide free method for hemoglobin

Performance

Parameter                 Linearity Range                 Precision(CV%)

WBC (10⁹/L)               0-200                                   2.5 (7.0-15.0)

RBC (1012/L)              0-8.00                                  2 (3.50-6.50)

HGB (g/L)                   0-280                                   1.5 (110-180)

MCV (fL)                                                                  1.0 (80.0-110.0)

PLT (10⁹/L)                  0-3000                                4 (150-500)

Sample Volume

Prediluted                20uL

Whole Blood            17uL

Throughput

60 samples per hour

Display

Large color touch screen

Resolution: 800x600

Carryover

WBC, RBC, HGB<0.5%, PLT<1.0%

PCCD BC-3600

AUTOMATED HEMATOLOGY ANALYZER

TECHNICAL SPECIFICATIONS
pccd bc3600.JPG
TECHNICAL SPECIFICATIONS

AUTOMATED HEMATOLOGY ANALYZER

PCCD BC-5000

Parameters

23 parameters: WBC, Lym%, Mon%, Neu%, Bas%, Eos%, Lym#, Mon#, Neu#, Eos#, Bas#, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT

3 histograms for WBC, RBC and PLT

3 scattergrams for WBC differential

Principles

Impedance method for RBC and PLT counting

Cyanide free reagent for hemoglobin test

Flow Cytometry (FCM) + Tri-angle laser scatter + Chemical dye method for WBC 5-part differential analysis and WBC counting

Performance

Parameter                 Linearity Range                 Precision(CV%)                 Carryover

WBC                            0-100x10⁹/L                       ≤2% (4-15x10⁹/L)              ≤0.5%

RBC                             0-8x1012/L                           ≤1.5% (3.5-6.0x1012/L)      ≤0.5%

HGB                            0-250g/L                             ≤1.5% (110-180g/L)           ≤0.6%

PLT                              0-1000x10⁹/L                     ≤4.0% (100-500x10⁹/L)     ≤1.0%

Reagent

Diluent, DIFF lyse, LH lyse, probe cleanser

Sample Volume

Prediluted                                       20uL

Whole Blood                                   17uL

Capillary whole blood mode        15uL

Throughput

40 samples per hour

Display

10.4 inch TFT Touch Screen

Multi-language

Chinese, English

pccd bc5000.JPG
TECHNICAL SPECIFICATIONS

Parameters

27: WBC, Lym%, Mon%, Neu%, Eos%, Bas%, Lym#, Mon#, Neu#, Eos#, Bas#, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, LIC%, LIC#, ALY%, ALY#

3 histograms and scattergram

Principles

Flow Cytometry (FCM), Semi-conductor Laser scatter, chemical dye method, Independent Basophil channel

Impedance method for WBC, RBC, PLT counting

Cyanide-free reagent for Hemoglobin test

Performance

Carryover                   Precision                                 Linearity

WBC ≤ 0.5%                ≤ 2.0% (4-15 x10⁹/L)              0.00-99.99x10⁹/L

RBC ≤ 0.5%                 ≤ 1.5% (3.5-6.0 x1012/L)         0.00-8.00 x1012/L    

HGB ≤ 0.5%                ≤ 1.5% (110-180g/L)              0-250g/L

PLT ≤1.0%                   ≤ 4.0% (150-500 x10⁹/L)        0-1000x10⁹/L    

Test Mode

CBC CBC+DIFF

Sample Volume

Prediluted                   20uL

Whole Blood               20uL

Throughput

Up to 60 samples per hour

PCCD BC-5300

AUTOMATED HEMATOLOGY ANALYZER

pccd bc5300.JPG
TECHNICAL SPECIFICATIONS

Parameters

27: WBC, Lym%, Mon%, Neu%, Eos%, Bas%, Lym#, Mon#, Neu#, Eos#, Bas#, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, LIC%, LIC#, ALY%, ALY#

3 histograms and scattergram

Principles

Flow Cytometry (FCM), Semi-conductor Laser scatter, chemical dye method, Independent Basophil channel

Impedance method for WBC, RBC, PLT counting

Cyanide-free reagent for Hemoglobin test

Performance

Carryover                   Precision                                 Linearity

WBC ≤ 0.5%                ≤ 2.0% (4-15 x10⁹/L)              0.00-99.99x10⁹/L

RBC ≤ 0.5%                 ≤ 1.5% (3.5-6.0 x1012/L)         0.00-8.00 x1012/L    

HGB ≤ 0.5%                ≤ 1.5% (110-180g/L)              0-250g/L

PLT ≤1.0%                   ≤ 4.0% (150-500 x10⁹/L)        0-1000x10⁹/L    

Test Mode

CBC CBC+DIFF

Sample Volume

Prediluted                   20uL

Whole Blood               20uL

Throughput

Up to 60 samples per hour

Up to 50 samples per hour with closed tube

PCCD BC-5380

AUTOMATED HEMATOLOGY ANALYZER

pccd bc5380.JPG
TECHNICAL SPECIFICATIONS

AUTOMATED HEMATOLOGY ANALYZER

PCCD BC-5800

Parameters

25 parameters: WBC, Lym%, Mon%, Neu%, Eos%, Lym#, Mon#, Neu#, Eos#, Bas#, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, P-LCR, P-LCC

4 Research parameters include LIC%, LIC#, ALY%, ALY#

2 Histograms for RBC and PLT

2 Scattergrams: 4-differential scattergram, Basophil scattergram

Principles

Impedance method for RBC and PLT counting

Cyanide free reagent for hemoglobin test

Flow Cytometry (FCM) + Laser light scatter + Chemical dye method for WBC differential analysis and WBC counting

Performance

Parameter                   Linearity Range                   Precision                               Carryover

WBC                              0-250x10⁹/L                         ≤2.5% (4-15x10⁹/L)              ≤0.5%

RBC                               0-8.2x1012/L                        ≤1.5% (3.5-6.0x1012/L)         ≤0.5%

HGB                              0-260g/L                               ≤1.5% (110-180g/L)             ≤1.0%

HCT                               0-67%                                   ≤1.5% (30%-50%)                 ≤0.5%

PLT                                0-2000x10⁹/L                       ≤4.0% (100-500x10⁹/L)        ≤1.0%

Reagent

Diluent, LEO(I), LEO(II), LBA, LH

All reagents configured liquid sensor

Sample Volume

Prediluted                                                          40uL

Manual mode(Open vial)                                 120uL

Auto loader/Manual mode (Closed tube)     180uL

Throughput

Up to 90 samples per hour

Display

10.4 inch TFT Touch Screen

Resolution: 800x600

pccd bc5800.JPG
TECHNICAL SPECIFICATIONS

Performance

Item                              Precision, CV

WBC                              2.0%

RBC                               1.9%

HGB                              1.9%

MCV                               0.4%

PLT                                 4.0%

Carry over WBC           2%, RBC 1%, HGB 2%, PLT 2% 

1.  Test Principle: Electrical resistance for counting and SFT method for HGB

2.  Test Flow: Fully auto and the blood unrequired dilute or other process

3.  Quantity Technology: Ultra sound quantity method, resistance from disturb

4.  Clot Clear: High voltage burn and high pressure flush

5.  Parameter: 3 part differentiation of WBC, 20 paramaters + 3 histograms

6.  Sample Mode: Venous, Capilary and prediluted blood

7.  Throughput: 35 samples/hour

8.  Language: English

9.  QC Mode: X, X-R, X-B, L-J, auto draw and print QC figure

10. Calibration Mode: Auto mode and manual mode are selectable, provide original

       calibrator and control

11. Reference Range Type: Newborn, children, male, female and universal

12. Reagent: Provide original reagent

13. Memory: Save more than 30,000 samples' details results including histograms

14. Display: Large colour LCD with touch screen, show all parameters and histograms at

       same screen

15. Input and Output: Keyboard, mouse, parallel port, RS232 serial port, can be

      connected to computer

16. Printer: Inner thermal printer, can be connected to external computer and printer

17. Working Environment: Temperature: 10°C~35°C, Humidity: ≤ 85%RH

18. Voltage: AC 175V~265V, Auto adaption according to the input voltage

19. Dimension: 565mm*467mm*571mm (L*W*H)

20. Net Weight: 30kg

 

PCCD KT 6200

AUTOMATED HEMATOLOGY ANALYZER

pccd kt6200.JPG
PCCD KT6200.jpg
PCCD 5000.jpg
PCCD BC 5800.jpg
PCCD BC 5300.jpg
PCCD BC 5000.jpg