CHEMISTRY ANALYZER
FULLY-AUTOMATED
SAMPLE/REAGENT POSITION
- 40pcs sample position
- Reagent refrigerated function
- 40pcs reagent position
REACTION CUVETTES
- 60pcs reusable plastic cuvettes
- Automatic blank testing for cuvette
- Colorimetry system in the pattern of light splitting behind cuvette
- Dismountable, easily replacement
SAMPLE/REAGENT/MIXING PROBE
- Automatic liquid level detect
- Collision protection function
- Probe internal/external washing
- Independent mixing probe
7-STEP AUTO CLEANING SYSTEM
- Automatic 7-step washing
- Hi-tech washing station to ensure accurate results
- With low water consumption: 1-2L/H
SYSTEM FUNCTIONS
- Analysis Methods: end-point, kinetic, two-point, double-reagent, double-wavelength, multi-standard etc, open to various reagents
SAMPLE/REAGENTS HANDLING
- Sample volume: 1.6-50uL, 0.1uL step
- Sample Dilution: automatic/Manual pre-dilution, with dilution ratio up to 1:100
- Reagent Position: 40pcs
- Reagent Volume: 10-500uL, 0.5uL step
TC200
FULLY AUTOMATED CHEMISTRY ANALYZER

OVERALL PERFORMANCE
Equipment Type
Analysis Rate
Test Principle
Analysis Method
SAMPLE SYSTEM
Sample Tray
Sample Volume
Sample Probe
Sample Containers
​
REAGENT SYSTEM
Reagent Tray
Reagent Volume
Reagent Probe
Reagent Refrigeration
Fully automatic discrete, STAT priority.
Constant speed 300T/H. (without ISE)
Colorimetry, turbidimetry.
End-point 2 kinetics, fixed-time etc
single/double wavelength, linear and non-linear calibration.
49 Sample positions, random access of all samples
2-50ul, 0.1ul increment.
Liquid level detection, the remaining detection, collision protection etc.
Sample cups, Micro tube. Original blood-collection tube, etc.
56 reagent positions
R1:25-300ul, R2:10-15ul, 0.1ul increment
Liquid level detection, the remaining detection, collision protection etc.
4-15°C, independent power supply, 24-hour non-stop refrigeration.
NT 300
FULLY AUTOMATED CHEMISTRY ANALYZER

FEATURES
- Fully automatically, discrete, random STAT function
- Online test items: at most 40 testing items
- Throughput: 260 tests/hour
- Analysis Method: end-point, kinetic, two-point, double
- Reagents, double-wavelength, multi-standard etc, open to various reagents
- Data Processing: memory up to 200,000 patient's data
SAMPLE/REAGENTS HANDLING
-Sample Position: 40pcs (Include standard, QC, STAT positions)
- Sample volume: 2-50uL, 0.1 uL step
- Sample Probe Cleaning: automatic internal & external washing
- Sample Dilution: automatic/Manual pre-dilution, with dilution ratio up to 1:100
- Reagent Position: 40pcs (with refirgerated function, 2°C-8°C)
- Reagent Probe: automatic liquid detect, with collision protection function
- Reagent Probe Cleaning: automatic internal & external washing
REACTION SYSTEM
- Reaction Cuvette: 90ocs made of reusable plastic
- Opical Length of Cuvette: 6mm
- Reaction Volume: 200-500uL
- Reaction Time: 8-10 minutes
- Reaction Temperature: 37°c-0.1°c
- Mixing System: Independent mixing stirrer
OPTICAL SYSTEM
- Light Source: halogen-tungsten lamp
QC
- Various QC managements, insert QC randomly; save, display & print QC chart; define different QC in advance
TC6030
FULLY AUTOMATED CHEMISTRY ANALYZER

FEATURES
- Fully automatically, discrete, random STAT function
- Online test items: at most 80 testing items
- Throughput: 400 tests/hour
- Analysis Method: end-point, kinetic, two-point, double
- Reagents, double-wavelength, multi-standard etc, open to various reagents
- Data Processing: memory up to 2 million patient's data
SAMPLE/REAGENTS HANDLING
-Sample Position: 93pcs (Include standard, QC, STAT positions)
- Sample volume: 2-50uL, 0.1 uL step
- Sample Probe Cleaning: automatic internal & external washing
- Sample Dilution: automatic/Manual pre-dilution, with dilution ratio up to 1:100
- Reagent Position: 40pcs (with refrigerated function, 2°C-8°C)
- Reagent Probe: automatic liquid detect, with collision protection function
- Reagent Probe Cleaning: automatic internal & external washing
REACTION SYSTEM
- Reaction Cuvette: 90pcs made of reusable plastic
- Optical Length of Cuvette: 6mm
- Reaction Volume: 200-500uL
- Reaction Time: 8-14 minutes
- Reaction Temperature: 37°c-0.1°c
- Mixing System: two Independent mixing stirrer
OPTICAL SYSTEM
- Light Source: halogen-tungsten lamp
- Wavelength: 340-750nm, 12 wavelengths, precision 2nm
- Spectrophotometry: rear spectroophotometry
- Test Range: 0-4.0 Abs
- Resolution: 0.001Abs
TC6090
FULLY AUTOMATED CHEMISTRY ANALYZER

SEMI-AUTOMATED

Test mode: Kinetic, End point, Two point, Absorbance
Wavelength: 7 standard filters, 340,405,492,510,546,578,630nm, 1 free position
Wavelength precision: ±2nm, width ≤ 10nm
Absorbance range: 0~4.500 Abs
Absorbance precision: outside 0.0001 Abs, inside 0.00001 Abs
Carryover: <1%
Repeatability CV: <1%
Incubator: 37°C, 30°C, 25°C, and others, Precision: ±0.1°C
Sample Volume: 0~3000ul (500ul recommend)
Data Storage: 10000
Quality control curve: X SD CV% L-J quality control curve for each test item
Flow cell: 32 ul quartz glass, 10mm
Lamp: Philips 6V 10W halogen lamp with longer life time
Screen: 7 inch color LCD
CPU: ARM series high speed micro CPU
Printer: Internal thermal sensitive printer
Interface: RS-232
Work Environment: Temperature 0°C~40°C, Humidity: 80%
Power supply: 100~240VAC, 50~60Hz, 100VA
Dimension: L340mm*W270mm*H160mm
Weight: 5kg
Liver Function: ALT AST ALP T-BIL TP ALB TTT CHE NH3
Renal Fucntion: BUN CRE UA URE CO2-CP Y-GT
Lipids: T-CHO TG HDL-C LDL-C
Cardiac function: CK CK-MB LDH
Immun proteins: IGA IGG IGM C3
Others: GLU HGB AMS
iCHEM 535
SEMI-AUTOMATED CHEMISTRY ANALYZER
Instrument: Fully-Auto Glycated Hemoglobin HbA1c Analyzer
Model: JL 760
Test Method: Low pressure ion exchange liquid chromatography (LPLC)
Test Item: HbA1ab HbA1c
Sample Type: Whole blood, hemolysis blood
Sample Volume: Whole blood 20ul, hemolysis blood 800ul
Photometer: 415nm LED Integral flow colorimeter
Analysis Time: 3.5mins
Precision: CV ≤ 3.0%
Display: 320*240 LC Graphic display, displaying real-time testing curve
Printer: 58nm Thermal printer, printing test curve and report
Panel: 0-9, YES, NO, START, STOP, ST, PRINT
Data Storage: 2G TF Card, more then 100,000 test reports storage (including Curve)
USB Port: Support remote upgrading, LIS Interface
PS-2 Port: External Barcode Scanner
Power Supply: 220V ± 22V, 50Hz ± 1Hz
Working Environment: Temperature 10°C~30°C, Relative humidity 30%~75%
Size: 550mm*405mm*347mm
Weight: 15kg
JL 760 (LPLC)
GLYCOSYLATED
HEMOGLOBIN

GLYCOSYLATED HEMOGLOBIN
Instrument: Fully-Auto Glycated Hemoglobin HbA1c Analyzer
Method: High pressure ion exchange liquid chromatography (HPLC)
Sampling System: Automatic identification system for Primary Tube & sample cup
Primary tube with cap puncture automatically
Throughput: <3mins per sample
Sample Tray: 15 samples position CAL (QC1) & CAL2 (QC2) position, ST
Sample Type: Venous Blood, Finger Peripheral Blood or hemolyse blood
Sample Volume: 5uL whole blood, or lyse blood (ratio 5uL:1000uL)
Test Range: HbA1c: 3-18%; 14-191mmol/mol, HbF:0.3-5%
Test Item: HbA1c HbF & B-Thalassemia
Heat system: Temperature range for column 5-40°c, can keep the constant
temperature, the fluctuation +-0.2°c
Light system: 415nm LED light, long life span, the fluctuation is 2mv per hour
Printer: 57mm Thermal printer, printing test curve and report
USB Port: Support LIS system, software upgrade online, external barcode scanner
optional
Barcode: External Barcode Scanner optional
Display: 8 inch LCD colorful touch screen, 162mm*122mm display real-time testing
curve
Data Storage: more than 10,000 test reports storage (including Curve), Inquiry freely
Language: English, Spanish, Russian, Portugese, Japanese
Report: NGSP, IFCC result
HbA1a, HbA1b, HbF, HbA1c, HbA0, variant sample report.
Optional PC software for regular report format
Work Condition: Temperature 5°C~40°C, Relative humidity 30%~75%
Dimension: 460mm*445mm*390mm
Weight: 28kgs
NH-20 (HPLC)
GLYCOSYLATED
HEMOGLOBIN