top of page

URINE ANALYZER

TECHNICAL SPECIFICATIONS

Parameters: pH, Nitrite, Ascorbic Acid, Protein, Specific Gravity, Blood, Glucose,

                        Bilirubin, Urobilinogen, Ketone, Leucocytes

Measurement Principle: Dual wavelength reflectance method

Measuring Wavelength: 3 LED Wavelength (550, 620, 720nm)

Reaction Time: 60 seconds

Throughput: 520 samples/hour

Display: LCD screen

Memory Capacity: 5000 results (3000 results with barcode)

Strip: URIT 10G/11G urine reagent strips

Interface: Serial port (RS232), parallel port (For external printer), PS/2 (For barcode

                    reader)

Work condition: Environmental Temperature: 15-30°C, RH: 20% ~ 80%

Power supply: 100~240V AC, 50/60Hz

Dimension: 390mm*340mm*290mm

Weight: 6.5kg

- Easy maintenance design with auto waste collection

- High test speed, ideal for extensive sample laboratory

- Fully automatic operation for ready-to-test

- Internal calibration for sensitivity of strips

- Cold light source facility with long life and high stability

- RS232 serial interface to host PC/LIS, Bracode reader optional

BA 600

SEMI-AUTOMATED URINE READER

BA600.JPG
TECHNICAL SPECIFICATIONS

Parameters: pH, Nitrite, Ascorbic Acid, Protein, Specific Gravity, Blood, Glucose,

                        Bilirubin, Urobilinogen, Ketone, Leucocytes

Measurement Principle: Dual wavelength reflectance method

Measuring Wavelength: 3 LED Wavelength (550, 620, 720nm)

Reaction Time: 60 seconds

Throughput: 520 samples/hour

Display: LCD screen

Memory Capacity: 5000 results (3000 results with barcode)

Strip: URIT 10G/11G urine reagent strips

Interface: Serial port (RS232), parallel port (For external printer), PS/2 (For barcode

                    reader)

Work condition: Environmental Temperature: 15-30°C, RH: 20% ~ 80%

Power supply: 100~240V AC, 50/60Hz

Dimension: 390mm*340mm*290mm

Weight: 6.5kg

- Easy maintenance design with auto waste collection

- High test speed, ideal for extensive sample laboratory

- Fully automatic operation for ready-to-test

- Internal calibration for sensitivity of strips

- Cold light source facility with long life and high stability

- RS232 serial interface to host PC/LIS, Bracode reader optional

PCCD 500

SEMI-AUTOMATED URINE READER

pccd 500.JPG
TECHNICAL SPECIFICATIONS

1. The color touch screen display menu operation interface, very convenient

2. The automatic collecting waste paper (forward)

3. The new optical sensor, high sensitivity, strong anti-jamming

4. The built-in high speed low noise thermal printers

5. The standard RS-232 interface, can connect to the computer for data exchange

6. The standard parallel port can be directly driven external printer to print the results

7. The user can freely set cut-off anomaly index mark

8. The sensitivity of each project can be adjusted through software interface

9. The specimen bar code scanner to automatically scan

ITEM                                TECHNICAL STANDARD

Principle                        Reflection photometer determine the color changes of urine strip

                                         and calculate related concentration values, then output semi-

                                         quantitative results

Wavelength                   525nm, 565nm, 620nm, 660nm

Scope of detection      LEU, NIT, URO, PRO, PH, BLD, SG, KET, BIL, GLU, VC, CA, CRE, MCA,

                                         Ratio of MCA and CRE, Total 15 items

Test strip type              8A, 10A, 11A, 12A, 13A, 14A

Detection speed          180 reports/hour

Report way                   liquid crystal display, serial port output, internal 57nm thermal printing

                                         with english and chinese, external pin type printing with english and

                                         chinese

Screen                            800*480 TFT-LCD Color touch screen

Input mode                   Color touch screen operation, the specimen bar code scanning inpput,

                                         the strip bar code scanning identification

Report Memory           Memory 5000 reports

Power Consumption   50VA

Size                                  405*335*220mm

Weight                            5kg

PCCD 550

SEMI-AUTOMATED URINE READER

pccd 550.JPG
TECHNICAL SPECIFICATIONS

Parameters: pH, Nitrite, Ascorbic Acid, Protein, Specific Gravity, Blood, Glucose,

                        Bilirubin, Urobilinogen, Ketone, Leucocytes

Measurement Principle: Dual wavelength reflectance method

Measuring Wavelength: 3 LED Wavelength (550, 620, 720nm)

Reaction Time: 60 seconds

Throughput: 520 samples/hour

Display: LCD screen

Memory Capacity: 5000 results (3000 results with barcode)

Strip: URIT 10G/11G urine reagent strips

Interface: Serial port (RS232), parallel port (For external printer), PS/2 (For barcode

                    reader)

Work condition: Environmental Temperature: 15-30°C, RH: 20% ~ 80%

Power supply: 100~240V AC, 50/60Hz

Dimension: 390mm*340mm*290mm

Weight: 6.5kg

- Easy maintenance design with auto waste collection

- High test speed, ideal for extensive sample laboratory

- Fully automatic operation for ready-to-test

- Internal calibration for sensitivity of strips

- Cold light source facility with long life and high stability

- RS232 serial interface to host PC/LIS, Bracode reader optional

PCCD 580

SEMI-AUTOMATED URINE READER

pccd 580.JPG
TECHNICAL SPECIFICATIONS

Parameters: RBC, WBC, SQEP (squamous epithelial cells), NSE (non-squamous

                        epithelial cells), pathological casts, mucus, crystals, bacteria, yeast, sperm

                        and others

Principles of operation: Auto microscopic measurement with flat flow cell

Counting cell: double channels, thickness of inner chamber: 0.1mm

Throughput: 40~60 samples/hour

                        Three types test mode: fast, standard, refined

Test mode: Auto loader mode. STAT mode

Bar code: internal auto bar code reader

Sample: native urine samples or urine sediment samples

Sample volume: 2.0 ml

Memory Capacity: more than 50,000 results (include images)

Connection: receive URIT series urine analyzer test data, available for connect URIT-

                       1500 Automatic Urine Analyzer

Interfaces: USB, RS232 serial port, parallel interface, LAN port

Power supply: AC100~220V, 50Hz

Dimension: 650*670*640 mm

Weight: 60kg

- Double counting channels in flow cell

- Whole view field microscopic images of sediment

- Automatic identification and classification of urine particles

- Walk-away automation, high efficient washing system

- High-efficiency washing system, automatic flow cell and probe washing system

PCCD 1200

AUTOMATED URINE SEDIMENT ANALYZER

pccd 1200.JPG
TECHNICAL SPECIFICATIONS

Parameters: Glucose, Protein, Blood, Bilirubin, pH, Ketone, Ascorbic Acid, Urobilinogen,  Nitrite, Leucocytes, Special Gravity Creatinine, Microalbumin, MA/CR, Color

Principle: Dual-wavelength reflectance photometry

Measuring Wavelength: 4 Wavelengths (525,620,720,470nm)

Strip Reaction Time: 60 seconds

Throughput: 225 samples/hour

Test mode: Continue loader mode, Manual mode STAT mode

Memory Capacity: 300,000 results

Strip type: URIT 11F, URIT 12F

Strip Capacity: 200 strips

Required Urine Volume: 2ml

Batch size: 110 samples, 10 samples x 11 racks

Display: Large touch screen

Printer: Built-in thermal printer, external printer

Interfaces: USB, RS232 Serial port, PS/2, parallel interface, LAN port

Work condition: Environmental Temperature: 15~30°C, RH: 20%~80%

Power Supply: AC 100~240V, 50/60Hz, 250VA

Dimension: 533*610*535 mm

Weight: 40kg

- Intelligent operations system

- Automatic sampling and waste strips discarding system

- Emergency inserting function to conduct the single emergency test

- Accurate quantitative sampling system to avoid cross contamination

- Advanced high luminosity cold light to improve accuracy, sensitivity and stability

- Automatically rectify test results influenced by ambient temperature, non-specificity, pH, specific gravity and color

- Integrated barcode reader for sample ID and rack ID

PCCD 1500

AUTOMATED URINE ANALYZER

pccd 1500.JPG
TECHNICAL SPECIFICATIONS

1. The color touch screen display menu operation interface, very convenient

2. The automatic collecting waste paper (forward)

3. The new optical sensor, high sensitivity, strong anti-jamming

4. The built-in high speed low noise thermal printers

5. The standard RS-232 interface, can connect to the computer for data exchange

6. The standard parallel port can be directly driven external printer to print the results

7. The user can freely set cut-off anomaly index mark

8. The sensitivity of each project can be adjusted through software interface

9. The specimen bar code scanner to automatically scan

ITEM                                TECHNICAL STANDARD

Principle                        Reflection photometer determine the color changes of urine strip

                                         and calculate related concentration values, then output semi-

                                         quantitative results

Wavelength                   525nm, 565nm, 620nm, 660nm

Scope of detection      LEU, NIT, URO, PRO, PH, BLD, SG, KET, BIL, GLU, VC, CA, CRE, MCA,

                                         Ratio of MCA and CRE, Total 15 items

Test strip type              8A, 10A, 11A, 12A, 13A, 14A

Detection speed          180 reports/hour

Report way                   liquid crystal display, serial port output, internal 57nm thermal printing

                                         with english and chinese, external pin type printing with english and

                                         chinese

Screen                            800*480 TFT-LCD Color touch screen

Input mode                   Color touch screen operation, the specimen bar code scanning inpput,

                                         the strip bar code scanning identification

Report Memory           Memory 5000 reports

Power Consumption   50VA

Size                                  405*335*220mm

Weight                            5kg

PCCD YH1520A

SEMI-AUTOMATED URINE READER

pccd yh1520a.JPG
bottom of page