PPE (Personal Protective Equipment) SOLUTIONS
Are you protected from the face mask you're wearing?
1. 3 Ply Medical Protection Mask
3 Layers
¤ 1st Layer - Hydrophobic Non-Woven Layer (translucent)
¤ 2nd Layer - Middle Melt-Blown Layer (white)
¤ 3rd Layer - Inner Soft Absorbent Non-Woven Layer (blue)
95-99%
Protection from virus
1 Pack (10pcs)



2. UV Lamp Disinfectant / Sterilizer
Double arm
Single arm

ZXC-II UV lamp L type double tube
(30W*2) stainless steel
UV Wavelength:
253.7nm
Power Source:
AC220V (50HZ)
Adjustment angle of lamp arm:
0-135° (II model)
Timing range:
0~60 minutes Illumination: 100μw/cm²Light:
Quartz light tube ,30W x2
Service life of Quartz light tube:
3000Hours
Working effective range:
60~90 squre meters room
Application range:
Used for air sterilization in all sorts of sanitary medical units or departments, scientific research units, pharmaceutical and food-process industry, etc.
Structure features
• Double tubes structure, which can also be used independently.
• Angle of lamp arm can be adjusted. In order to protect tubes from dust and damage, please leave protection door shut while it doesn't work.
• Sterilization timing range: 0~ 60 minutes for sterilization. Once sterilization is finished, buzzer rings, circuit breaks down and pipe turns off.
• Do circuit test before use to make sure if there is no leakage prior to application

ZXC-II UV lamp Y type double arm
(30W *4) stainless steel
UV Wavelength:
253.7nm
Power Source:
AC220V (50HZ)
Adjustment angle of lamp arm:
0-135° (II model)
Timing range:
0~60 minutes
Illumination: 100μw/cm²
Light: Quartz light tube,30W x4
Service life of Quartz light tube:
3000Hours
Working effective range:
120~180 squre meters room (30W*4)
Application range:
Used for air sterilization in all sorts of sanitary medical units or departments, scientific research units, pharmaceutical and food-process industry, etc.
Structure features
• Double tubes structure, which can also be used independently.
• Angle of lamp arm can be adjusted. In order to protect tubes from dust and damage, please leave protection door shut while it doesn't work.
• Sterilization timing range: 0~ 60 minutes for sterilization. Once sterilization is finished, buzzer rings, circuit breaks down and pipe turns off.
• Do circuit test before use to make sure if there is no leakage prior to application

ZXC-II UV lamp double tube steel, spray
(30W*2) Steel coated with powder
UV Wavelength:
253.7nm
Power Source:
AC220V (50HZ)
Adjustment angle of lamp arm:
0-135° (II model)
Timing range:
0~60 minutes
Illumination: 100μw/cm²
Light: Quartz light tube, 30W x2
Service life of Quartz light tube:
3000Hours
Working effective range:
60~90 squre meters room (30W*2)
Application range:
Used for air sterilization in all sorts of sanitary medical units or departments, scientific research units, pharmaceutical and food-process industry, etc.
Structure features
• Double tubes structure, which can also be used independently.
• Angle of lamp arm can be adjusted. In order to protect tubes from dust and damage, please leave protection door shut while it doesn't work.
• Sterilization timing range: 0~ 60 minutes for sterilization. Once sterilization is finished, buzzer rings, circuit breaks down and pipe turns off.
• Do circuit test before use to make sure if there is no leakage prior to application

ZXC-II UV lamp double tube Y type Double Arm
steel, spray (30W*4) Steel coated with powder
UV Wavelength:
253.7nm
Power Source:
AC220V (50HZ)
Adjustment angle of lamp arm:
0-135° (II model)
Timing range:
0~60 minutes
Illumination: 100μw/cm²
Light: Quartz light tube, 30W x2
Service life of Quartz light tube:
3000Hours
Working effective range:
60~90 squre meters room (30W*4)
Application range:
Used for air sterilization in all sorts of sanitary medical units or departments, scientific research units, pharmaceutical and food-process industry, etc.
Structure features
• Double tubes structure, which can also be used independently.
• Angle of lamp arm can be adjusted. In order to protect tubes from dust and damage, please leave protection door shut while it doesn't work.
• Sterilization timing range: 0~ 60 minutes for sterilization. Once sterilization is finished, buzzer rings, circuit breaks down and pipe turns off.
• Do circuit test before use to make sure if there is no leakage prior to application

Optional Remote Control
.
Application range:
for 30W*2 vertion UV Lamp
5 meters effective remote control distance
control panel update

UV Lamp Disinfectant (Table Type)
.
• Good for Home / Personal use
• Area covered 30-50 sq m

Disinfection Vehicle (A)
23CM*22CM
96CM
100W
Three gear timing switch + Remote dual control
No ozone/ozone

Disinfection Vehicle (B)
23CM*22CM
96CM
150W
Three gear timing switch + Remote dual control
No ozone/ozone

UV Lamp (Spare lamp)
UVC-100W/150W
1. 220V 50-60HZ
2. Power: 100W or 150W
3. 254nm No ozone or without Ozone



Portable/Handy UV Lamp





3. Face Shield




4. Medical Gloves (available in Medium & Large sizes)

5. KN95 Mask