Parameters

WBC, LY#, MID#, GR#, LY%, MID%, GR%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, DRW-CV, PLT, MPV, PDW, PCT, P-LCR and Histogarm for WBC, RBC, PLT

Method

Coulter Principle

Colorimtery hamoglobin determination

Performance

Parameter                 Linearity Range                 Precision(CV%)

WBC (10⁹/L)               0.0-99.9                              2.5 (7.0-15.00

RBC (1022/L)              0.00-9.99                            2.0 (3.50-6.00)

HGB (g/L)                    0-300                                  1.5 (110-180)

MCV (fL)                      40.0-150.0                          0.5 (80.0-110.0)

PLT (10⁹/L)                 0-999                                   5.0 (200-500)

Throughput

60 samples per hour

Menu

Review, Test, Maintenance, QC, Setup, Shutdown, Prime reagents, System diagnosis, Aperture rinse, Soak and Rinse, Calibration, instrument config.

Display

8.0" color LCD display

Sampler Volume

Predilute            20uL

Whole blood     15uL

TECHNICAL SPECIFICATIONS

AUTOMATED HEMATOLOGY ANALYZER

PCCD 5000

pccd5000.JPG

Parameters

WBC, LY#, MID#, GR#, LY%, MID%, GR%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, PDW, PCT, P-LCR, P-LCC and Histogarm for WBC, RBC, PLT

Principles

Electrical impedance method for cell counting and cyanide free method for hemoglobin

Performance

Parameter                 Linearity Range                 Precision(CV%)

WBC (10⁹/L)               0-200                                   2.5 (7.0-15.0)

RBC (1012/L)              0-8.00                                  2 (3.50-6.50)

HGB (g/L)                   0-280                                   1.5 (110-180)

MCV (fL)                                                                  1.0 (80.0-110.0)

PLT (10⁹/L)                  0-3000                                4 (150-500)

Sample Volume

Prediluted                20uL

Whole Blood            17uL

Throughput

60 samples per hour

Display

Large color touch screen

Resolution: 800x600

Carryover

WBC, RBC, HGB<0.5%, PLT<1.0%

PCCD BC-3600

AUTOMATED HEMATOLOGY ANALYZER

TECHNICAL SPECIFICATIONS
pccd bc3600.JPG
TECHNICAL SPECIFICATIONS

AUTOMATED HEMATOLOGY ANALYZER

PCCD BC-5000

Parameters

23 parameters: WBC, Lym%, Mon%, Neu%, Bas%, Eos%, Lym#, Mon#, Neu#, Eos#, Bas#, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT

3 histograms for WBC, RBC and PLT

3 scattergrams for WBC differential

Principles

Impedance method for RBC and PLT counting

Cyanide free reagent for hemoglobin test

Flow Cytometry (FCM) + Tri-angle laser scatter + Chemical dye method for WBC 5-part differential analysis and WBC counting

Performance

Parameter                 Linearity Range                 Precision(CV%)                 Carryover

WBC                            0-100x10⁹/L                       ≤2% (4-15x10⁹/L)              ≤0.5%

RBC                             0-8x1012/L                           ≤1.5% (3.5-6.0x1012/L)      ≤0.5%

HGB                            0-250g/L                             ≤1.5% (110-180g/L)           ≤0.6%

PLT                              0-1000x10⁹/L                     ≤4.0% (100-500x10⁹/L)     ≤1.0%

Reagent

Diluent, DIFF lyse, LH lyse, probe cleanser

Sample Volume

Prediluted                                       20uL

Whole Blood                                   17uL

Capillary whole blood mode        15uL

Throughput

40 samples per hour

Display

10.4 inch TFT Touch Screen

Multi-language

Chinese, English

pccd bc5000.JPG
TECHNICAL SPECIFICATIONS

Parameters

27: WBC, Lym%, Mon%, Neu%, Eos%, Bas%, Lym#, Mon#, Neu#, Eos#, Bas#, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, LIC%, LIC#, ALY%, ALY#

3 histograms and scattergram

Principles

Flow Cytometry (FCM), Semi-conductor Laser scatter, chemical dye method, Independent Basophil channel

Impedance method for WBC, RBC, PLT counting

Cyanide-free reagent for Hemoglobin test

Performance

Carryover                   Precision                                 Linearity

WBC ≤ 0.5%                ≤ 2.0% (4-15 x10⁹/L)              0.00-99.99x10⁹/L

RBC ≤ 0.5%                 ≤ 1.5% (3.5-6.0 x1012/L)         0.00-8.00 x1012/L    

HGB ≤ 0.5%                ≤ 1.5% (110-180g/L)              0-250g/L

PLT ≤1.0%                   ≤ 4.0% (150-500 x10⁹/L)        0-1000x10⁹/L    

Test Mode

CBC CBC+DIFF

Sample Volume

Prediluted                   20uL

Whole Blood               20uL

Throughput

Up to 60 samples per hour

PCCD BC-5300

AUTOMATED HEMATOLOGY ANALYZER

pccd bc5300.JPG
TECHNICAL SPECIFICATIONS

Parameters

27: WBC, Lym%, Mon%, Neu%, Eos%, Bas%, Lym#, Mon#, Neu#, Eos#, Bas#, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, LIC%, LIC#, ALY%, ALY#

3 histograms and scattergram

Principles

Flow Cytometry (FCM), Semi-conductor Laser scatter, chemical dye method, Independent Basophil channel

Impedance method for WBC, RBC, PLT counting

Cyanide-free reagent for Hemoglobin test

Performance

Carryover                   Precision                                 Linearity

WBC ≤ 0.5%                ≤ 2.0% (4-15 x10⁹/L)              0.00-99.99x10⁹/L

RBC ≤ 0.5%                 ≤ 1.5% (3.5-6.0 x1012/L)         0.00-8.00 x1012/L    

HGB ≤ 0.5%                ≤ 1.5% (110-180g/L)              0-250g/L

PLT ≤1.0%                   ≤ 4.0% (150-500 x10⁹/L)        0-1000x10⁹/L    

Test Mode

CBC CBC+DIFF

Sample Volume

Prediluted                   20uL

Whole Blood               20uL

Throughput

Up to 60 samples per hour

Up to 50 samples per hour with closed tube

PCCD BC-5380

AUTOMATED HEMATOLOGY ANALYZER

pccd bc5380.JPG
TECHNICAL SPECIFICATIONS

AUTOMATED HEMATOLOGY ANALYZER

PCCD BC-5800

Parameters

25 parameters: WBC, Lym%, Mon%, Neu%, Eos%, Lym#, Mon#, Neu#, Eos#, Bas#, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, P-LCR, P-LCC

4 Research parameters include LIC%, LIC#, ALY%, ALY#

2 Histograms for RBC and PLT

2 Scattergrams: 4-differential scattergram, Basophil scattergram

Principles

Impedance method for RBC and PLT counting

Cyanide free reagent for hemoglobin test

Flow Cytometry (FCM) + Laser light scatter + Chemical dye method for WBC differential analysis and WBC counting

Performance

Parameter                   Linearity Range                   Precision                               Carryover

WBC                              0-250x10⁹/L                         ≤2.5% (4-15x10⁹/L)              ≤0.5%

RBC                               0-8.2x1012/L                        ≤1.5% (3.5-6.0x1012/L)         ≤0.5%

HGB                              0-260g/L                               ≤1.5% (110-180g/L)             ≤1.0%

HCT                               0-67%                                   ≤1.5% (30%-50%)                 ≤0.5%

PLT                                0-2000x10⁹/L                       ≤4.0% (100-500x10⁹/L)        ≤1.0%

Reagent

Diluent, LEO(I), LEO(II), LBA, LH

All reagents configured liquid sensor

Sample Volume

Prediluted                                                          40uL

Manual mode(Open vial)                                 120uL

Auto loader/Manual mode (Closed tube)     180uL

Throughput

Up to 90 samples per hour

Display

10.4 inch TFT Touch Screen

Resolution: 800x600

pccd bc5800.JPG